The key to success for a modern professional print business is automation and accuracy. The Konica Minolta FD-9 Autoscan Spectrophotometer is the ideal tool for print colour management, combining speed, accuracy, ease-of-use and versatility.
Fast
• 1500 patches in just 4 minutes
• M0, M1 and M2 in one single scan
Versatile
• Measures virtually every chart including control wedges
• Compatible with a wide variety of substrates
• Virtual Fluorescence Standard for non-standard viewing environments
Connected
• USB and Ethernet connection
• QR code reader
Accurate
• Automatic wavelength calibration
• Temperature drift compensation
• Self-check function
Accessories
- AC Adapter
- USB Cable (3 m) IF-A18
- Measurement Utility Software FD-S2w
- Auto Sheet Feeder FD-A09
- Color Management Software basICColor series
Color tiles
Specifications
Model | FD-9 | |
Illumination/viewing system | 45°a: 0°(annular illumination) *1 | |
Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164 and JIS Z. 8722 Condition A for reflectance measurements. | ||
Spectral separation device | Concave grating | |
Wavelength range | 380 ~ 730 nm | |
Wavelength pitch | 10 nm | |
Half bandwidth | Approx. 10 nm | |
Measurement area | Approx. Ø 3 mm | |
Light source | LED | |
Measurement range | Reflectance: 0 to 150% | |
Short-term repeatability | Colorimetric: Within σΔ E00 0.05 (Without polarization filter) | |
* Under Konica Minolta test conditions where a white calibration plate is measured 30 times at 10- second intervals after white calibration | ||
Inter-instrument agreement | Within E00 0.3 (Average of 12 BCRA Series II colour tiles compared to values measured with a master body under Konica Minolta standard conditions; without polarization filter) | |
Measurement time | Approx. 4 min per 1,500 patches *Konica Minolta measurement conditions*3 |
|
Output item | Spectral reflectance | |
Measurement conditions *2 | M0 (A), M1 (D50) , M2 (A + UV filter), C, ID50, D65, ID65, F2, F6, F7, F8, F9, F10, F11, F12, User-defined light source | |
Backing condition | White backing, compliant with ISO13655 | |
Interface | USB2.0, 10Base-T/100Base-TX | |
Power | Specified AC adapter (Input: AC 100 to 240 V, 50/60 Hz; Output: DC 24 V, 5 A) | |
Size | FD-9 only: W716 x D251 x H159 mm Auto Sheet Feeder: W601 x D1,158 (when tray is open) x H245 mm |
|
Weight | FD-9 only: Approx. 10.5 kg | |
Operating temperature/ humidity range |
10 to 35°C, 30 to 85% relative humidity with no condensation | |
Storage temperature/humidity range |
0 to 45°C, 0 to 85% relative humidity with no condensation | |
Standard accessories | AC adapter, USB cable, Measurement Utility software FD-S2w | |
Optional accessory | Auto Sheet Feeder FD-A09 |
Width | 45 ~ 330mm | |
Length | 170 ~ 1500 mm | |
Thickness | 0.05 ~ 0.45 mm | |
Smallest patch size | 6×6 mm | |
Maximum patches per sheet | 1,394(A4) 2,928(A3) |
Operating environment | OS | Windows 7 / Windows 8.1 / Windows 10 Mac OS X 10.9-10.10 |
|
CPU | 1 GHz or faster processor | ||
Memory | 1 GB or more (32 bit)/ 2 GB or more (64 bit) |
||
Hard disk | At least 8 GB of available disk space | ||
Display | Display unit capable of showing at least 1,024 x 768 dots | ||
Interface | USB 2.0, 10Base-T/100Base-TX | ||
Compatible instruments | FD-9 FD-7/CL-500A (Readout only for user-defined light source) |
||
Features | Chart creation, chart measurement, measurement data display, measurement file output, QR code creation | ||
Displayed measurement data | Spectral reflectance, colorimetric value, density | ||
Measurement conditions *2 |
M0 (A), M1 (D50) , M2 (A + UV filter), C, ID50, D65, ID65, F2, F6, F7, F8, F9, F10, F11, F12, User-defined light source | ||
Illuminants | A, C, D50, ID50, D65, ID65, F2, F6, F7, F8, F9, F10, F11, F12, A + UV filter, User-defined light source | ||
Observers | 2° or 10° Standard Observer | ||
Colour spaces | L*a*b*, L*C*h, XYZ | ||
PC supported languages | English, French, German, Spanish, Japanese, Chinese (Simplified) | ||
Output format | CxF3: ISO17972-1:2015 CGATS: ISO28178:2009 (ANSI CGATS-17) FD-S2w original format (csv/tsv) |
*1 Unidirectional illumination for wavelengths of 400 nm and below
*2 M0, M1 and M2 are lighting conditions contained in ISO13655 “4.2.2 Illumination requirements and measurement conditions.”
*3 Chart size: A3, Patch size: 6 x 6 mm, Patch layout: 47 rows x 32 columns
Features
The FD-9 reads 1,500 patches in just 4 minutes and 2,500 patches in just 7 minutes. Within one single scan users obtain data for M0, M1 and M2, conforming to ISO13655:2009 and offering improved certainty of colours and OBA.
The FD-9 uses a free-format function enabling it to measure virtually every chart that might be used to calibrate printers and create profiles.
Even quality control wedges, used for conformance testing of proof prints, etc., can be measured with the FD-9 without cutting them from the print.
Users can obtain amazing results and achieve the best possible neutral grey balance and flawless skintones in even non-standard viewing environments. Konica Minolta’s Virtual Fluorescent Standard (VFS) allows the creation of precision custom profiles to compensate for the environment where the print will be viewed.
The FD-9 features both USB and Ethernet connectivity enabling you to easily share one FD-9 between multiple machines.
The integrated image scanner enables automatic chart alignment and can read QR codes for fully automated sheet and chart identification.
The colour display shows step by step instructions to the operator, improving usability and minimising the opportunity for user error. The results of a quality control evaluation can be viewed directly on the display*1.
Like the groundbreaking FD-7, the FD-9 features built-in wavelength calibration and temperature drift compensation, maximising day-to-day accuracy and reliability.
For repair, certification and adjustments to absolute accuracy, Konica Minolta offers worldwide standardized service for all instruments. Users can be confident of Inter Model and Inter Instrument Agreement between the FD-5, FD-7 and FD-9 to offer their customers true local or global consistency.
Users who want to monitor and audit the absolute accuracy of the system on a regular basis will benefit from the optional self-check function of FD-9. Self check uses certified BCRA tiles specifically designed for FD-9 to monitor the accuracy at any time.
Measuring a large number of patches with FD-9 is both fast and convenient. Users who need to measure dozens of sheets every day can benefit from using the Automatic sheet feeder, a first for a print colour measurement instrument. This optional accessory enables up to 100 sheets to be pre-loaded and measured with minimal user input. Combined with the QR code reader function, the measurement results can be automatically inked to the printed sheet.
Software
- basICColor catch 5
- CGS ORIS Press Matcher // Web
- CGS ORIS Color Tuner // Web
- CGS ORIS Certified // Web
- ColorLogic ColorAnt 4
- Creo Color Servers
- Durst Workflow-Label
- EFI Fiery Digital Frontends
- EFI Color Profiler Suite
- Heidelberg Color Toolbox 17
- Konica Minolta ColorCentro
- Konica Minolta ColorCare Suite
- Konica Minolta ColorCare Server
- Konica Minolta Falbard Aqua
- Konica Minolta FD-s2w
- ONYX PosterShop, ProductionHouse and Thrive 12.1 and higher
Dedicated FD-9 charts are available. Measurement values are imported from FD-s2w.
- Caldera V11
- systemata Inkjet.Perfect
- systemata Laser.Perfect
- systemata Tif.Perfect CTP/CTF
- systemata PDF.Perfect
Measurements from FD-s2w can be imported into every software supporting the CGATS (ISO 28178) file format for characterization data e.g.
- basICColor CMYKick, dropRGB, print, Devil, ImProve
- ColorLogic CoPrA, ColorAnt < Version 4
Company names and product names mentioned here are the registered trademarks or trademarks of their respective companies.